Design and Analysis of Under Ground Rectangular Water Tank by using STAAD.PRO

Authors

  • Eslavath Nithin U.G. Student, Department of Civil Engineering,, Guru Nanak Institutions Technical Campus, Ibrahimpatnam, Telangana, India
  • Keerthi Venu U.G. Student, Department of Civil Engineering,, Guru Nanak Institutions Technical Campus, Ibrahimpatnam, Telangana, India.
  • Kelothu yakub U.G. Student, Department of Civil Engineering,, Guru Nanak Institutions Technical Campus, Ibrahimpatnam, Telangana, India.
  • Rajesh D V S P Assistant Professor, Department of Civil Engineering, Guru Nanak Institutions Technical Campus, Ibrahimpatnam, Telangana, India.

Keywords:

IS 1893-2002(PART-2), Retaining Tanks, Staad.pro V8i, IS 3370: 2009 (Part I-IV)

Abstract

Storage reservoirs and underground tank are used to store water, liquid petroleum, petroleum products and similar liquids. The force analysis of the reservoirs or tanks is about the same irrespective of the chemical nature of the product. All tanks are designed as crack free structures to eliminate any leakage. This project gives in brief, the theory behind the design of liquid retaining structure (circular water tank with flexible and rigid base and rectangular underground water tank) using working stress method. This report also includes computer subroutines to analyze and design circular water tank with flexible and rigid base and rectangular underground water tank. The program has been written as Macros in Microsoft Excel using Visual Basic programming language. In the end, the programs are validated with the results of manual calculation given in Concrete Structure book.

Downloads

Published

2024-12-12

How to Cite

Nithin, E., Venu, K., yakub, K., & D V S P, R. (2024). Design and Analysis of Under Ground Rectangular Water Tank by using STAAD.PRO . Erudite Journal of Engineering, Technology and Management Sciences, 4(4), 40–44. Retrieved from https://ejetms.com/index.php/ejetms/article/view/54